Precision Testing & Calibration Instruments ☎ +60 12-345 6789 ✉ products@devinetestinstruments.com
DEVINE Testing Instruments
Low Temperature Blackbody Furnace

small size high precision surface source blackbody furnace (radiation surface 70mm)

The blackbody calibration source is a standard for infrared radiation. It is widely used in the technical index test of the process test and the qualification t

✉ WhatsApp
  • Enquiry-based quotation
  • Technical & calibration support
  • Worldwide enquiries welcome

Description

Product Introduction

The blackbody calibration source is a standard for infrared radiation. It is widely used in the technical index test of the process test and the qualification test during the development of the infrared detector. It can complete the response uniformity, response curve and death of the photosensitive surface of the infrared focal plane device. In the test of parameters such as element pixels. At the same time, the area source blackbody radiation source is the core equipment of the infrared imaging prism collimation device, and it cooperates with the infrared collimation optical system and infrared target to complete the key technical index test and performance evaluation of the infrared imaging system. It can meet the testing requirements of infrared imagers in my country's newly developed infrared imaging guided weapons, and can meet the testing requirements of infrared thermal imaging cameras that are widely used in medical, construction, security monitoring, environmental testing and other industries.

Product Feature

  • More portable and lighter. Higher precision.
  • Human-machine interface, Chinese display, touch operation, beautiful and elegant.
  • One-key temperature setting, simple operation. Rapid heating and temperature control.
  • According to customer requirements, the language interface of multiple countries and regions can be copied for easy export.

Technical Indicators

Model

Temperature Range

-10℃–100℃

Control Mode

4-inch touch screen operation

Temperature Resolution

0.1℃/0.01℃

Temperature Control

PID Automatic Control

Radiating Surface

70mm ×70mm

Cavity depth

10mm

Emissivity

≥0.95

Temperature Stability

≤0.15%t℃/10min

Temperature Uniformity

Not more than ±0.2℃ and 0.2%t, t is the radiation source temperature (within 2/3 center area)

Power Supply

220V AC 50/60Hz

Wire Line Diameter

≥1.5㎡

Power

350W

Dimension(L×W×H)

134mm×134mm×185mm

Weight

≤2Kg

Environment

22±3℃ 15%RH-65%RH; max height 2000 meters

Communication method

Special remarks if communication is required

Communication method

Support 485 Communications

Remark

Low-temperature surface source blackbody furnace, when the set temperature is lower than the ambient temperature, in order to effectively avoid the problem of frost on the radiation surface of the blackbody furnace, the blackbody furnace is equipped with an anti-frost cover, and the user needs to prepare nitrogen, nitrogen pressure reducing valve and other related supporting equipment.

Specifications

Model
Temperature Range10℃--100℃
Control Mode4-inch touch screen operation
Temperature Resolution0.1℃/0.01℃
Temperature ControlPID Automatic Control
Radiating Surface70mm ×70mm
Cavity depth10mm
Emissivity≥0.95
Temperature Stability≤0.15%t℃/10min
Temperature UniformityNot more than ±0.2℃ and 0.2%t, t is the radiation source temperature (within 2/3 center area)
Power Supply220V AC 50/60Hz
Wire Line Diameter≥1.5㎡
Power350W
Dimension(L×W×H)134mm×134mm×185mm
Weight≤2Kg
Environment22±3℃ 15%RH-65%RH; max height 2000 meters
Communication methodSpecial remarks if communication is required
Communication methodSupport 485 Communications
RemarkLow-temperature surface source blackbody furnace, when the set temperature is lower than the ambient temperature, in order to effectively avoid the problem of frost on the radiation surface of the blackbody furnace, the blackbody furnace is equipped with an anti-frost cover, and the user needs to prepare nitrogen, nitrogen pressure reducing valve and other related supporting equipment.