Surface Thermometer Calibration Furnace
Product Introduction
- Enquiry-based quotation
- Technical & calibration support
- Worldwide enquiries welcome
Description
Product Introduction
Product Introduction
The surface temperature calibration system is mainly used to calibrate various sizes and types of surface sensors, such as thermistors, thin film sensors, surface resistance thermometers, strip sensors, surface thermocouples, etc. This product consists of a controller and a heater, which is easy to operate, visually displayed, and can start heating by simply setting the temperature. The temperature rises quickly, and the multi-stage PID temperature control is accurate.
Product features
Accurate and reliable: Accuracy ± 0.5 ℃ @ 300 ℃, ± 1 ℃ @ 400 ℃
Rapid heating: It only takes 25 minutes from room temperature to 400 ℃
High stability: ± 0.2 ℃ @ 200 ℃, ± 0.3 ℃ @ 300 ℃, ± 0.4 ℃ @ 400 ℃
Multi stage temperature control: Equipped with multiple short PID controllers, it can achieve segmented temperature control, with small overshoot and overshoot, rapid heating, and small temperature control fluctuations
There is a standard socket on the side, which can be inserted directly below the center of the measurement surface to improve calibration accuracy
Supports RS232 communication and can be equipped with communication software
The temperature uniformity and surface smoothness of the calibration plane are excellent
Surface sensors are often difficult to calibrate because it is difficult to find a flat, uniform surface temperature source. The surface temperature calibration system uses special alloy materials as the surface, with high smoothness, which can ensure good contact between the calibrated sensor and the surface temperature calibrator, thereby reducing calibration uncertainty. Using special heating materials and constant temperature structure, the surface temperature is more uniform.
Portable and easy to use, the whole machine is compact and portable, very suitable for laboratory or on-site use.
Technical Indicators
Temperature Range
Room Temperature +5℃~400℃
Calibration Plane Diameter
100mm
Accuracy
±0.5℃@200 ℃; ±1.0 ℃ @ 400 ℃
Temperature Rise Time
Room Temperature +5℃~400℃,25min
Stability
±0.2℃@200℃; ±0.3℃@300℃; ±0.4℃@400℃
Stable Time
8min
Resolution
0.1℃
Uniformity
0.3℃(RT+5℃<t<100℃), 0.7℃(100℃<t<300℃),1.2℃(300℃<t<400℃),
Display Resolution
0.1℃
Power Supply
220VAC/50HZ/2000W
Equipment Dimension
340mm*300mm*170mm
Temperature Controller Dimension
230mm*220mm*110mm
Weight
4Kg
Storage Condition
-20 to 60℃ 5%RH-90%RH
Specifications
| Temperature Range | Room Temperature +5℃~400℃ |
|---|---|
| Calibration Plane Diameter | 100mm |
| Accuracy | ±0.5℃@200 ℃; ±1.0 ℃ @ 400 ℃ |
| Temperature Rise Time | Room Temperature +5℃~400℃,25min |
| Stability | ±0.2℃@200℃; ±0.3℃@300℃; ±0.4℃@400℃ |
| Stable Time | 8min |
| Resolution | 0.1℃ |
| Uniformity | 0.3℃(RT+5℃<t<100℃), 0.7℃(100℃<t<300℃),1.2℃(300℃<t<400℃), |
| Display Resolution | 0.1℃ |
| Power Supply | 220VAC/50HZ/2000W |
| Equipment Dimension | 340mm*300mm*170mm |
| Temperature Controller Dimension | 230mm*220mm*110mm |
| Weight | 4Kg |
| Storage Condition | 20 to 60℃ 5%RH-90%RH |